PVC Insulated and Sheathed Cables with flexible copper conductor for working voltage upto 1100 volts
Nominal Area Of Conductor | Number / Diameter Of Wire | Resistance Per Km @ 20º C (Max) | Current Carrying Capacity in Amps.as per IS:3961 | Nominal Thickness of Insulation | Over All Diameter (Max) | ||||
---|---|---|---|---|---|---|---|---|---|
Sq.mm | mm | Ohms | On Cable Tray | Concealed | mm | mm | |||
Plain Copper | Tinned Copper | Single Phase | Three Phase | Single Phase | Three Phase | ||||
0.5
|
16/0.2
|
39
|
40.1
|
4 |
- |
- |
- |
0.6 |
2.6 |
0.75 |
24/0.2 |
26 |
26.7 |
7 |
- |
- |
- |
0.6 |
2.8 |
1.0 |
32/0.2 |
19.5 |
20.0 |
12 |
12 |
11 |
9 |
0.6 |
3.0 |
1.5 |
30/0.25 |
13.3 |
13.7 |
16 |
15 |
13 |
11 |
0.6 |
3.4 |
2.5 |
50/0.25
|
7.98 |
8.21 |
22 |
20 |
18 |
16 |
0.7 |
4.1 |
4.0 |
56/0.3 |
4.95 |
5.09 |
29 |
26 |
33 |
20 |
0.8 |
4.8 |
6.0 |
84/0.3 |
3.30 |
3.39 |
37 |
33 |
24 |
25 |
0.8 |
5.3 |
10
|
140/0.3
|
1.91
|
1.95
|
51
|
45
|
42 |
35 |
1.0
|
7.0
|
16
|
126/0.4 |
1.21 |
1.24 |
68 |
61 |
57 |
48 |
1.0 |
8.1 |
25 |
196/0.4 |
0.780 |
0.795 |
86 |
78 |
71 |
60 |
1.2 |
10.2 |
35 |
276/0.4 |
0.554 |
0.565 |
110 |
99 |
91 |
77 |
1.2 |
11.7 |
50 |
396/0.4 |
0.386 |
0.393 |
145 |
135 |
120 |
100 |
1.4 |
13.9 |
70 |
354/0.5 |
0.272 |
0.277 |
200 |
180 |
165 |
145 |
1.4 |
16.0 |
95 |
480/0.5 |
0.206 |
0.210 |
235 |
215 |
33 |
165 |
1.6 |
18.2 |
120 |
607/0.5 |
0.161 |
0.164 |
270 |
240 |
225 |
195 |
1.6 |
20.2 |
150 |
760/0.5 |
0.129 |
0.132 |
310 |
280 |
- |
- |
1.8 |
22.5 |
185 |
941/0.5 |
0.106 |
0.108 |
360 |
320 |
- |
- |
2.0 |
24.9 |
240 |
1221/0.5 |
0.0801 |
0.817 |
425 |
385 |
- |
- |
2.2 |
28.4 |
300 |
1527/0.5 |
0.0641 |
0.0654 |
490 |
440 |
- |
- |
2.4 |
31.0 |
Note:
a) Upto 4.00 Sqmm X 5 Core cables are flexible category Class - 5
b) Above 4.00 Sqmm all Multicore cables are fixed wiring cables (Class - 5 Copper construction pattern)
c) Upto 4.00 Sqmm Braided & Shielded Cables are available
2 Core | 3 Core | 4 Core | 5 Core | 6 - 25 Core |
---|---|---|---|---|
Red, Black |
Red, Yellow, Blue OR Red, Black, Yellow/Green |
Red, Yellow, Blue, Black, OR Red, Blue,Black, Yellow/Green |
Red, Yellow, Blue, Black, Grey |
As per IS 694 or As per requirement |
POWER CORD FLEXIBLE MULTI CORE CABLES : (Generally conforming to IS:694 : 1990)
PVC Insulated Unsheathed Cables with flexible copper conductor for working voltage upto 1100 volts
Nominal Area Of Conductor |
Number / Diameter Of Wire |
Resistance per Km @ 20°C (Max) |
Current Carrying Capacity (in Amps) as per IS : 3961 |
Nominal Thikness of Insulation |
Nominal Thikness of Sheath / (Max) Diameter Of Sheath |
||||
---|---|---|---|---|---|---|---|---|---|
Sq.mm |
mm |
Ohms |
Single or Three Phase |
Flat Twin Core |
Flat Twin Core |
Twin Circular |
Three Core |
Four Core |
Five Core |
0.5 |
16/0.2 |
39.0 |
4 |
0.6 |
0.9 / 4.9x7.2 |
0.9 / 7.2 |
0.9 / 7.6 |
0.9 / 7.6 |
0.9 / 8.7 |
0.75 |
24/0.2 |
26.0 |
7 |
0.6 |
0.9 / 5.2x7.8 |
0.9 / 7.8 |
0.9 / 8.2 |
0.9 / 8.2 |
0.9 / 9.2 |
1.0 |
32/0.2 |
19.5 |
11 |
0.6 |
0.9 / 5.4x8.0 |
0.9 / 8.0 |
0.9 / 8.6 |
0.9 / 8.6 |
1.0 / 9.6 |
1.5 |
30/0.25 |
13.3 |
14 |
0.6 |
0.9 / 5.6x8.6 |
0.9 / 8.6 |
0.9 / 9.2 |
0.9 / 9.2 |
1.0 / 11.4 |
2.5 |
50/0.25 |
7.98 |
19 |
0.7 |
1.0 / 6.6x10.5 |
0.9 / 10.5 |
1.0 / 11.0 |
1.0 / 11.0 |
1.0 / 13.2 |
4.0 |
56/0.3 |
4.95 |
26 |
0.8 |
1.0 / 7.4x12.0 |
1.0 / 12.0 |
1.0 / 12.5 |
1.0 / 12.5 |
1.1 / 15.5 |
PINS DATA (Just for information)
SPECIFICATION |
As per IS : 1293 : 2005 |
||
WORKING VOLTAGE |
2.5 Amps, 6Amps/10 Amps & 16 Amps |
||
SIZE |
POLE |
EARTHING |
|
For 2.5 Amps (2 Pin) | 5.08 |
----- |
|
For 6 Amps/10Amps | 5.08 |
7.06 |
|
For 16 Amps | 7.06 |
8.71 |
SRINI LINK 1.00 SQ.MM X 3 C UP TO 1100 V I S : 694 (RoHS)
FLEXIBLE EXTRA MULTI CORE CABLES (6 to 25 Cores)
PVC Insulated and Sheathed Cables with flexible copper conductor for working voltage upto 1100 volts
Generally conforming to IS 694 : 2010
Area SQ.MM | 0.50 |
0.75 |
1.00 |
1.50 |
2.50 |
No. of Strands / Nominal Dia. of strands | 16/0.2 |
24/0.2 |
32/0.2 |
30/0.25 |
50/.25 |
Nominal Insulation Thickness in mm | 0.60 |
0.60 |
0.60 |
0.60 |
0.70 |
Max. Diameter in mm | 2.60 |
2.80 |
3.00 |
3.40 |
4.10 |
Number of Cores |
Lay up |
Nominal Sheath thickness in mm / Maximum overall diameter in mm |
||||
6 |
6 |
0.9 / 9.5 |
1.0 / 10.0 |
1.0 / 10.5 |
1.0 / 12.4 |
1.1 / 14.5 |
7 |
1-6 |
0.9 / 9.5 |
1.0 / 10.0 |
1.0 / 10.5 |
1.0 / 12.4 |
1.1 / 14.5 |
8 |
1-7 |
1.0 / 11.1 |
1.0 / 11.8 |
1.0 / 12.4 |
1.1 / 14.7 |
1.2 / 17.3 |
9 |
1-8 |
1.0 / 11.8 |
1.1 / 12.4 |
1.1 / 13.1 |
1.1 / 15.6 |
1.3 / 18.3 |
10 |
2-8 |
1.0 / 12.0 |
1.1 / 12.7 |
1.1 / 13.4 |
1.1 / 16.0 |
1.3 / 18.7 |
11 |
3-8 |
1.1 / 12.0 |
1.1 / 12.7 |
1.1 / 13.4 |
1.1 / 16.0 |
1.3 / 18.7 |
12 |
3-9 |
1.0 / 12.4 |
1.1 / 13.1 |
1.1 / 13.9 |
1.1 / 16.5 |
1.3 / 19.4 |
13 |
3-10 |
1.0 / 13.1 |
1.1 / 13.8 |
1.1 / 14.6 |
1.2 / 17.4 |
1.3 / 20.5 |
14 |
4-10 |
1.1 / 13.1 |
1.1 / 13.8 |
1.1 / 14.6 |
1.2 / 17.4 |
1.3 / 20.5 |
15 |
5-10 |
1.1 / 13.5 |
1.2 / 14.3 |
1.2 / 15.1 |
1.2 / 18.1 |
1.4 / 21.3 |
16 |
5-11 |
1.1 / 13.8 |
1.2 / 14.6 |
1.2 / 15.4 |
1.2 / 18.4 |
1.4 / 21.7 |
17 |
5-12 |
1.1 / 14.6 |
1.2 / 15.4 |
1.2 / 16.3 |
1.3 / 19.5 |
1.4 / 23.0 |
18 |
0-6-12 |
1.1 / 14.6 |
1.2 / 15.4 |
1.3 / 16.3 |
1.3 / 19.5 |
1.4 / 23.3 |
19 |
1-6-12 |
1.1 / 13.2 |
1.2 / 14.9 |
1.3 / 15.6 |
1.3 / 17.1 |
1.4 / 20.3 |
20 |
1-7-12 |
1.2 / 15.4 |
1.3 / 16.3 |
1.4 / 17.3 |
1.4 / 20.7 |
1.5 / 24.4 |
21 |
1-7-13 |
1.2 / 15.4 |
1.3 / 16.3 |
1.4 / 17.3 |
1.4 / 20.7 |
1.5 /25.0 |
22 |
2-7-13 |
1.2 / 16.3 |
1.3 / 17.3 |
1.4 / 18.2 |
1.4 / 21.9 |
1.5 / 25.8 |
23 |
2-8-13 |
1.2 / 16.3 |
1.3 / 17.3 |
1.4 / 18.2 |
1.4 / 21.9 |
1.5 / 26.3 |
24 |
2-8-14 |
1.2 / 17.1 |
1.3 / 18.2 |
1.4 / 19.2 |
1.4 / 23.0 |
1.5 / 27.2 |
25 |
2-8-15 |
1.2 / 17.1 |
1.3 / 19.0 |
1.4 / 19.2 |
1.4 / 23.0 |
1.5 / 27.2 |
Max. Conductor Resistance in Ohm/Km at 20°C.
|
39.00 |
26.00 |
19.50 |
13.30 |
7.98 |
|
Approx. recommended Current Rating in Amps for 3 Phase
|
4 |
7 |
10 |
14 |
18 |