Building Wires

Building wires (FR / FR-LSH / HFFR)


SRiNi LiNK Fire Retardant (FR) Building Wires, are one of the best protector against current sparking and fire.

SRiNi LiNK FR Building Wires are manufactured by keeping all the aspects & specification of ISI & International standards, which makes our cable one of the best product for your home & office.

Use SRiNi LiNK FR Building Wires for durability & safety.

FR WIRES: Fire Retardant - RoHS PVC Insulated Building Wires

Application: FR Building wires are mainly used in House, Commercial & Industrial Building, etc for internal, external & concealed wiring and also in panel boards wiring & electricity distribution board wiring.

Conductor: With Bright-annealed EC grade copper with 99.90 to 99.97% purity, which offers low conductor resistance, lower heating and save the power consumption.

RoHS Insulation : The FR PVC insulation formulation is of TYPE A, TYPE C & TYPED category. Along with maintaining Standard required concentration of oxygen & temperature index along with better insulation resistance and di-electric strength, which helps in:

- Where ever due to electrical spark flame take place, its Oxygen index and temperature index doesn't allow flame to prolong further.

Technical Specification as per IS : 694 : 2010: (Generally conforming to IS: 694 : 2010)

Technical Specification as per IS: 694:2010
Nominal Area Of ConductorNumber / Diameter Of WireNominal Thickness of InsulationMax Conductor Resistance Per Km @ 20' C ( Max )Current Carrying Capacity in Amps.as per IS:3961
Sq.mmmmmmOhmsOn Cable TrayConcealed Wiring
Single PhaseThree PhaseSingle PhaseThree Phase
0.5016/0.20.639.00/54---
0.7524/0.20.639.0077--
1.0014/0.30.726.001212119
1.5022/0.30.719.5016151311
2.5036/0.30.813.5022201816
4.0056/0.30.87.9829262420
6.0084/0.40.84.9537333125
10.00140/0.31.03.3051454235
16.00126/0.41.03.3068615748

TYPE TEST: FOR FR PVC

TestFunctionSpecificationTypical Values - Flame guard
Critical Oxygen IndexTo determine percentage of oxygen required for supporting combustion of insulating material at room temperatureIS 694More than 29%
Temperature IndexTo determine at what temperature normal oxygen content 21% in air will support combustion of insulating materialIS 694More than 250ºC.

SRiNi LiNK ® (FR) 1.00 SQ.MM UP TO 1100 V IS : 694 RoHS

Working Voltage : upto 1100 V

Colour Code : RED, BLACK, BLUE, YELLOW, GREEN & GREY

Packing for FR Wires: 90 Mtrs. box packing upto 4.00 SQ.MM / 45 Mtrs. / 200 Mtrs. / 300 Mtrs. / as per requirement

FR-LSH WIRES : Fire Retardant - Low Smoke Halogen RoHS PVC Insulated Building Wires

Application: These Cables are mainly used & recommended where more number of people are their or where different kinds of modern electrical equipments are used like Hospital, School & College, Malls, Hotels, Commercial Buildings & Govt. Offices or as per users.

Conductor: With Bright-annealed EC grade copper with 99.90 to 99.97% purity, which offers low conductor resistance, lower heating and save the power consumption.

RoHS Insulation :

FR-LSH PVC insulation formula is of TYPE-A or TYPE-D (C2 Category) and so well developed by us because of which, it maintain s more than the required IS:694 physical, chemical & mechanical properties.

Wherever due to any unavoidable circumstance fire take place at that time because of its properties, these cable doesn't supp ort flame where Oxygen index is below 29% or temperature index of that particular cable reaches to 2500C and beyond this if fire is at very massive level than its low smoke density and low halogen gas release properties helps people to stay conscious and evacuate easily by themselves or by fire safety people.

In short fire fighting becomes easy with SRiNi LiNK FR-LSH Wires.

TYPE TEST: FOR FR-LSH PVC

TestFunctionSpecificationTypical Values - Flame guard
Critical Oxygen IndexTo determine percentage of oxygen required for supporting combustion of insulating material at room temperatureIS 694More than 29%
Temperature IndexTo determine at what temperature normal oxygen content 21% in air will support combustion of insulating materialIS 694More than 250ºC
Smoke density (Light Transmission)To determine the visibility (light transmission) under fire of insulation materialASTM-D 2843More than 40%
Acid Gas GenerationTo ascertain the amount of hydro chlorine acid gas evolved from insulation of the cable under fireIS 694Less than 20%

HFFR WIRES: Halogen Free Fire Retardant PVC Insulated Building Wires

Application: These Cables are mainly used & recommended where more number of people are their or where different kinds of modern electrical equpments are used like Hospital, School & College, Malls, Hotels, Commercial Buildings & Govt. Offices or as per users.

Conductor: With Bright-annealed EC grade copper with 99.90 to 99.97% purity, which offer low conductor resistance, lower heating and save the power consumption.

RoHS Insulation :

FR-LSH PVC insulation formula is of TYPE-A or TYPE-D (C2 Category) and so well developed by us because of which, it maintain s more than the required IS:694 physical, chemical & mechanical properties.

Wherever due to any unavoidable circumstance fire take place at that time because of its properties, these cable doesn't support flame where Oxygen index is below 29% or temperature index of that particular cable reaches to 2500C and beyond this if fire is at very massive level than its low smoke density and negligible smoke & halogen gas release properties helps people to stay conscious and evacuate easily by themselves or by fire safety people

In short fire fighting becomes easy with SRiNi LiNK HFFR Wires.

TYPE TEST: FOR HFFR INSULATION

TestFunctionSpecificationTypical Values - Flame guard
Critical Oxygen IndexTo determine percentage of oxygen required for supporting combustion of insulating material at room temperatureASTM-D 2863More than 29%
Temperature IndexTo determine at what temperature normal oxygen content 21 % in air will support combustion of insulating materialASTM-D 2863More than 2500°C.
Smoke density (Light Transmission)To determine the visibility (light transmission) under fire of insulation materialASTM-D 2863More than 80%
Halogen Acid Gas GenerationTo ascertain the amount of hydrochloric acid gas evolved from insulation of cable under fireIEC 60754-1Less than 0.50%

Working Voltage : upto 1100 V

Colour Code : RED, BLACK, BLUE, YELLOW GREEN, YELLOW-GREEN & GREY

Packing : 90 Mtrs. / 100 Mtrs. / 45 Mtrs. / 200 Mtrs. / 300 Mtrs. / as per requirement